  • 0AWG 50MM Black Battery Cable Per Meter

    0AWG 50MM Black Battery Cable Per Meter

    Specification

    Conductor
    No. / Dia
    (mm)
    Nominal
    Area
    (mm²)
    Insulation
    Thickness
    (mm)
    Electrical
    Resistance
    at 20°C
    (ohm/km)
    Nominal
    O.D.
    (mm)
    Mass
    (kg/100m)
     
    322/0.2 10 1.0 1.91 6.3 11.4  
    511/0.2 16 1.0 1.21 7.3 17.1  
    784/0.2 25 1.2 0.78 8.8 30  
    1120/0.2 35 1.2 0.554 10.2 37.5  
    1568/0.2 50 1.4 0.386 11.9 51  
    2240/0.2 70 1.4 0.272 14 71.5  
    3040/0.2 95 1.6 0.206 16 97  
  • 0AWG 50MM Red Battery Cable Per Meter

    0AWG 50MM Red Battery Cable Per Meter

    Specification

    Conductor
    No. / Dia
    (mm)
    Nominal
    Area
    (mm²)
    Insulation
    Thickness
    (mm)
    Electrical
    Resistance
    at 20°C
    (ohm/km)
    Nominal
    O.D.
    (mm)
    Mass
    (kg/100m)
     
    322/0.2 10 1.0 1.91 6.3 11.4  
    511/0.2 16 1.0 1.21 7.3 17.1  
    784/0.2 25 1.2 0.78 8.8 30  
    1120/0.2 35 1.2 0.554 10.2 37.5  
    1568/0.2 50 1.4 0.386 11.9 51  
    2240/0.2 70 1.4 0.272 14 71.5  
    3040/0.2 95 1.6 0.206 16 97  
  • 2AWG 35MM Black Battery Cable Per Meter

    2AWG 35MM Black Battery Cable Per Meter

    Specification

    Conductor
    No. / Dia
    (mm)
    Nominal
    Area
    (mm²)
    Insulation
    Thickness
    (mm)
    Electrical
    Resistance
    at 20°C
    (ohm/km)
    Nominal
    O.D.
    (mm)
    Mass
    (kg/100m)
     
    322/0.2 10 1.0 1.91 6.3 11.4  
    511/0.2 16 1.0 1.21 7.3 17.1  
    784/0.2 25 1.2 0.78 8.8 30  
    1120/0.2 35 1.2 0.554 10.2 37.5  
    1568/0.2 50 1.4 0.386 11.9 51  
    2240/0.2 70 1.4 0.272 14 71.5  
    3040/0.2 95 1.6 0.206 16 97  
  • 2AWG 35MM Red Battery Cable Per Meter

    2AWG 35MM Red Battery Cable Per Meter

    Specification

    Conductor
    No. / Dia
    (mm)
    Nominal
    Area
    (mm²)
    Insulation
    Thickness
    (mm)
    Electrical
    Resistance
    at 20°C
    (ohm/km)
    Nominal
    O.D.
    (mm)
    Mass
    (kg/100m)
     
    322/0.2 10 1.0 1.91 6.3 11.4  
    511/0.2 16 1.0 1.21 7.3 17.1  
    784/0.2 25 1.2 0.78 8.8 30  
    1120/0.2 35 1.2 0.554 10.2 37.5  
    1568/0.2 50 1.4 0.386 11.9 51  
    2240/0.2 70 1.4 0.272 14 71.5  
    3040/0.2 95 1.6 0.206 16 97  
  • BP Connectors (Acorns) 240V 32A ea – Double Screw

    BP Connectors (Acorns) 240V 32A ea – Double Screw

    BP Double Screw Connector (Acorn)
    240V 32A

  • Plastic Cable Clip (For Solar Cable)

    Plastic Cable Clip (For Solar Cable)

    Plastic Cable Clip (For Solar Cable)

    The plastic cable clip is designed to be easily fitted into the solar rail to orderly sit the solar module cables.

  • Split Conduit 19MM – per meter

    Split Conduit 19MM – per meter

    Split Conduit 19MM – per meter

    – Dimensionally stable
    – Flexible
    – Crush-resistant
    – Low rodent-protection
    – Fast and easy assembly

  • Black cable entry gland M16 4-8mm

    Black cable entry gland M16 4-8mm

    Acts as a sealing and terminating device to ensure the protection of electrical equipment and enclosures.

    Cable diameter: 4 – 8mm
    Plate thickness: 8mm
    Thread: M16

  • Black cable entry gland M20 10-14mm

    Black cable entry gland M20 10-14mm

    Acts as a sealing and terminating device to ensure the protection of electrical equipment and enclosures.

    Cable diameter: 10 – 14mm
    Thread: M20

  • Copper Lug 4x6mm

    Copper Lug 4x6mm

    Copper Cable Lug – Standard

    Cable Size: 4mm²
    Bolt Size: 6mm

  • Copper Lug 25x10mm

    Copper Lug 25x10mm

    Copper Cable Lug – Standard

    Cable Size: 25mm²
    Bolt Size: 10mm

  • Copper Lug 50x8mm

    Copper Lug 50x8mm

    Copper Cable Lug – Standard

    Cable Size: 50mm²
    Bolt Size: 8mm