Shipping class: Free Shipping

Free Shipping
  • Victron CANvu GX IO Extender and wiring kit

    Victron CANvu GX IO Extender and wiring kit

    SKU 3565
    Model # BPP900800100
    Barcode # 8719076047889
    Brand Victron Energy
    Shipping Weight 0.5000kg
    Shipping Width 0.175m
    Shipping Height 0.090m
    Shipping Length 0.115m
    Shipping Cubic 0.019440000m3
  • Victron GX Tank 140

    Victron GX Tank 140

    The GX Tank 140 takes readings from up to four tank level sensors. It is an accessory for the Victron range of GX system monitoring products, such as the Cerbo GX Controller

    Tank levels can be read-out locally in the system, as well remotely through Victron’s VRM Portal.

    GX Tank 140 on GX Display

     

    GX Tank 140 Features:

    • Interfaces with either 4 to 20mA or 0 to 10V tank level sensors (including a combination of both).
    • Connection to the GX Device via USB interface.
    • Channel 1 and 2 use a fused power source from the Vin connection for sensor excitation.
    • Channel 3 and 4 use an integrated 24V power source for sensor excitation, which is powered via the USB interface.
    • The integrated 24V power source simplifies the installation/wiring process, as no additional power source is required.
    • Configurable input range, for example to connect a 0 to 5V sensor.
    • Configurable averaging filter (1 to 60 seconds) to dampen the effect of fluid movement.
    • Sensor fault detection: an alarm is raised if the input signal is out of normal/acceptable operating range.
    • Full integration with a GX device for configuration, monitoring and tank pump (relay) control.

     

    The GX Tank is compatible with current senders (4 to 20 mA) as well as voltage senders (0 to 10 V). The connection to the GX Device is via USB, which is also how the GX Tank is powered: no additional power wires required.

    Tank sender wiring is kept as simple as possible: two of the four inputs provide a 24 V power supply, to power the sender. The other two channels do require an external power supply, and there is a power in terminal together with fused outputs to facilitate that.

    Upper and lower limits are configurable, to allow using senders that provide only part of the scale, for example 0 to 5 V.

    To provide a stable reading, the readings are averaged damping. The damping can be configured between 1 and 60 seconds.

    Faulty sensors and wiring issues are detected: an alarm will be raised when values are out of range.

    For marine applications, the GX Device can transmit these tank levels on the NMEA 2000 network to be picked up by other displays such as an MFD.

     

    SKU 3587
    Model # BPP920140100
    Barcode # 8719076053781
    Brand Victron Energy
    Shipping Weight 0.1200kg
    Shipping Width 0.080m
    Shipping Height 0.090m
    Shipping Length 0.130m
    Shipping Cubic 0.000936000m3
    Unit Of Measure ea
  • Victron Skylla-i Control GX (Right Angle RJ45) Retail

    Victron Skylla-i Control GX (Right Angle RJ45) Retail

    The Skylla-i Control allows you to alter the charge current and see the system status.

    SKU 3604
    Barcode # 8719076024316
    Brand Victron Energy
    Shipping Weight 0.2150kg
    Shipping Width 0.155m
    Shipping Height 0.110m
    Shipping Length 0.050m
    Shipping Cubic 0.008800000m3
    Unit Of Measure ea
  • Victron Anti-islanding relay UFR1001E

    Victron Anti-islanding relay UFR1001E

    The Ziehl UFR1001E monitors voltage and frequency in plants for own generation of electricity. It fulfils the requirements of VDE-AR-N 4105 bdew-directive, G59/3, G83/2 and ÖVE/ÖNORM E 8001-4-712:2009 for generators connected to the public grid.

    The function of the output-relays and of the connected switches can be monitored with feedback contacts. When a connected switch does not switch off, the UFR does not switch on again. When a switch does not switch on it makes 2 restarts and thus improves the availability of the monitored plant.

    Voltage and Frequency Relay UFR1001E

    Energex approval RED STD00233

    SKU 3597
    Model # REL100100000
    Barcode # 8719076024408
    Brand Victron Energy
    Shipping Weight 0.3500kg
    Shipping Width 0.175m
    Shipping Height 0.110m
    Shipping Length 0.135m
    Shipping Cubic 0.002772000m3
  • Victron Energy Meter EM24 – 3 phase – max 65A/phase

    Victron Energy Meter EM24 – 3 phase – max 65A/phase

    SKU 3571
    Model # REL200100000
    Barcode # 8719076024422
    Brand Victron Energy
    Shipping Weight 0.4400kg
    Shipping Width 0.120m
    Shipping Height 0.075m
    Shipping Length 0.100m
    Shipping Cubic 0.009000000m3
  • Victron Energy Meter ET340 – 3 phase – max 65A/phase

    Victron Energy Meter ET340 – 3 phase – max 65A/phase

    SKU 3570
    Model # REL300300000
    Barcode # 8719076039693
    Brand Victron Energy
    Shipping Weight 0.2400kg
    Shipping Width 0.130m
    Shipping Height 0.075m
    Shipping Length 0.105m
    Shipping Cubic 0.010725000m3
  • Victron Autotransformer 120/240VAC-32A

    Victron Autotransformer 120/240VAC-32A

    The Victron Energy Autotransformer (AT) supports many different wiring configurations. It can increase your system’s ability to adapt to different design and Voltage requirements, and also be used to balance loads in split-phase 120/240Vac systems. Specialty systems such as boats and vehicles may face different shore configurations while travelling, an autotransformer can help by being flexible and enabling connections to most grid configurations.

    The Victron Energy Autotransformer has the ability to use a ground/earth relay to create a Neutral to Ground bond in the AT itself, if coupled with a Victron Energy MultiPlus or Quattro and the relay terminals are interconnected.

    Autotransformer Types of Use

    Balancing

    Balancing a Generator or Stacked Inverters

    Stepping Up Voltage

    Alternative to Stacked Inverters.

    Stepping Down Voltage

    Flexibility in Using Split-Phase for Single-Phase Inverters

    SKU 3686
    Model # ITR000100001
    Barcode # 8719076022404
    Brand Victron Energy
    Shipping Weight 15.0000kg
    Shipping Width 0.350m
    Shipping Height 0.450m
    Shipping Length 0.300m
    Shipping Cubic 0.047250000m3
  • Victron Autotransformer 120/240V-100A

    Victron Autotransformer 120/240V-100A

    The Victron Energy Autotransformer (AT) supports many different wiring configurations. It can increase your system’s ability to adapt to different design and Voltage requirements, and also be used to balance loads in split-phase 120/240Vac systems. Specialty systems such as boats and vehicles may face different shore configurations while travelling, an autotransformer can help by being flexible and enabling connections to most grid configurations.

    The Victron Energy Autotransformer has the ability to use a ground/earth relay to create a Neutral to Ground bond in the AT itself, if coupled with a Victron Energy MultiPlus or Quattro and the relay terminals are interconnected.

    Autotransformer Types of Use

    Balancing

    Balancing a Generator or Stacked Inverters

    Stepping Up Voltage

    Alternative to Stacked Inverters.

    Stepping Down Voltage

    Flexibility in Using Split-Phase for Single-Phase Inverters

    SKU 3687
    Model # ITR000100101
    Barcode # 8719076022428
    Brand Victron Energy
    Shipping Weight 15.0000kg
    Shipping Width 0.350m
    Shipping Height 0.450m
    Shipping Length 0.300m
    Shipping Cubic 0.047250000m3
  • Victron Isolation Tr. 7000W 230V

    Victron Isolation Tr. 7000W 230V

    Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

    Galvanic corrosion

    Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, fresh water are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, the conductivity of the fluid, temperature, nature of the materials, etc.

    It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact, it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply.

    Safety and prevention of galvanic corrosion

    The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. Safety is taken for granted in the case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire onboard results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

    The best solution

    To avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.

    Reduce galvanic corrosion with an Isolation Transformer Victron Energy

     

    Isolation Transformers 2000 Watt (1) 3600 Watt (1) 3600 Watt Auto 115/230 V (1) 7000 Watt
    Input 115 or 230 V 115 or 230 V 115 / 230 V
    Automatic 115/230 V switching
    230 V
    Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V
    Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
    Rating 17 / 8,5 A 32 / 16 A 32 / 16 A 32 A
    Soft start Yes
    Transformer type Toroidal (low noise, low weight)
    Input circuit breaker yes
    ENCLOSURE
    Common Characteristics Material: aluminium (blue RAL 5012)Protection category: IP 21
    Weight 10 Kg 23 Kg 24 Kg 31 Kg
    Dimensions (h x w x d), mm 375x214x110 362 x 258 x 218
    STANDARDS
    Safety EN 60076
    1) Can be used as:
    115 V to 115 V isolation transformer
    115 V to 230 V isolation transformer
    230 V to 230 V isolation transformer
    230 V to 115 V isolation transformer
    SKU 3684
    Model # ITR000702001
    Barcode # 8719076022442
    Brand Victron Energy
    Shipping Weight 32.1500kg
    Shipping Width 0.335m
    Shipping Height 0.435m
    Shipping Length 0.295m
    Shipping Cubic 0.044880000m3
  • Victron Isolation Tr. 2000W 115/230V

    Victron Isolation Tr. 2000W 115/230V

    Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

    Galvanic Corrosion

    Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, freshwater are such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, the conductivity of the fluid, temperature, nature of the materials, etc.

    It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply.

    Safety and prevention of galvanic corrosion

    The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. Safety is taken for granted in the case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire onboard results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

    The best solution

    To avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.

    Reduce galvanic corrosion with an Isolation Transformer Victron Energy

     

    Isolation Transformers 2000 Watt (1) 3600 Watt (1) 3600 Watt Auto 115/230 V (1) 7000 Watt
    Input 115 or 230 V 115 or 230 V 115 / 230 V
    Automatic 115/230 V switching
    230 V
    Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V
    Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
    Rating 17 / 8,5 A 32 / 16 A 32 / 16 A 32 A
    Soft start Yes
    Transformer type Toroidal (low noise, low weight)
    Input circuit breaker yes
    ENCLOSURE
    Common Characteristics Material: aluminium (blue RAL 5012)Protection category: IP 21
    Weight 10 Kg 23 Kg 24 Kg 31 Kg
    Dimensions (h x w x d), mm 375x214x110 362 x 258 x 218
    STANDARDS
    Safety EN 60076
    1) Can be used as:
    115 V to 115 V isolation transformer
    115 V to 230 V isolation transformer
    230 V to 230 V isolation transformer
    230 V to 115 V isolation transformer
    SKU 3682
    Model # ITR040202041
    Barcode # 8719076022480
    Brand Victron Energy
    Shipping Weight 13.5000kg
    Shipping Width 0.300m
    Shipping Height 0.440m
    Shipping Length 0.215m
    Shipping Cubic 0.029040000m3
  • Victron Isolation Tr. 3600W 115/230V

    Victron Isolation Tr. 3600W 115/230V

    Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

    Galvanic Corrosion

    Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, freshwater is such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, the conductivity of the fluid, temperature, nature of the materials, etc.

    It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply.

    Safety and prevention of galvanic corrosion

    The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. Safety is taken for granted in the case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire onboard results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

    The best solution

    To avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.

    Reduce galvanic corrosion with an Isolation Transformer Victron Energy

     

    Isolation Transformers 2000 Watt (1) 3600 Watt (1) 3600 Watt Auto 115/230 V (1) 7000 Watt
    Input 115 or 230 V 115 or 230 V 115 / 230 V
    Automatic 115/230 V switching
    230 V
    Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V
    Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
    Rating 17 / 8,5 A 32 / 16 A 32 / 16 A 32 A
    Soft start Yes
    Transformer type Toroidal (low noise, low weight)
    Input circuit breaker yes
    ENCLOSURE
    Common Characteristics Material: aluminium (blue RAL 5012)Protection category: IP 21
    Weight 10 Kg 23 Kg 24 Kg 31 Kg
    Dimensions (h x w x d), mm 375x214x110 362 x 258 x 218
    STANDARDS
    Safety EN 60076
    1) Can be used as:
    115 V to 115 V isolation transformer
    115 V to 230 V isolation transformer
    230 V to 230 V isolation transformer
    230 V to 115 V isolation transformer
    SKU 3683
    Model # ITR040362041
    Barcode # 8719076022527
    Brand Victron Energy
    Shipping Weight 25.0000kg
    Shipping Width 0.335m
    Shipping Height 0.435m
    Shipping Length 0.295m
    Shipping Cubic 0.044880000m3
  • Victron Isolation Tr. 3600W  Auto 115/230V

    Victron Isolation Tr. 3600W Auto 115/230V

    Indispensable in professional marine energy systems. It prevents electrolytic corrosion and above all serves as a device to guarantee a safe electric system. Toroidal wound technology for quietness and high efficiency. Soft start circuitry will ensure that the shore circuit breaker will not trip when plugged in.

    Galvanic Corrosion

    Galvanic corrosion occurs when two dissimilar metals in electrical contact are simultaneously exposed to an electrically conducting fluid. Seawater and, to a lesser extent, freshwater is such fluids. In general, the more active alloy of the couple corrodes preferentially while the less active (more noble) material is cathodically protected. The rate of galvanic corrosion is a function of several variables including area ratios, the conductivity of the fluid, temperature, nature of the materials, etc.

    It is a misunderstanding that galvanic corrosion occurs only in metal and aluminium hulls. In fact it can occur on any boat as soon as a metallic part (the shaft and propeller) is in contact with water. Galvanic corrosion will quickly dissolve your sacrificial anodes, and attack the shaft, propeller and other metal parts in contact with water as soon as the boat is connected to the shore-side supply. It might therefore be tempting not to connect the ground conductor: this is however extremely dangerous because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat. The best solution to avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply.

    Safety and prevention of galvanic corrosion

    The Isolation Transformer eliminates any electrical continuity between AC shore power and the boat. It is essential for safety and eliminates the need for galvanic isolators and polarity alarms. Safety is taken for granted in the case of a normal on-shore installation. A fuse will blow or a GFCI (Ground Fault Current Interrupter) will trip in case of a short circuit or current leakage to ground. Connecting the ground wire of the shore-side supply to the metal parts of the boat will result in galvanic corrosion (see below). Bringing only the live and neutral wire onboard results in an unsafe situation because GFCIs will not work nor will a fuse blow in case of a short circuit to a metal part on the boat.

    The best solution

    To avoid galvanic corrosion and at the same time prevent any unsafe situation is to install an Isolation Transformer to connect to the shore-side supply. The Isolation Transformer eliminates any electrical continuity between shore power and the boat. The shore power is fed to the primary side of the transformer and the ship is connected to the secondary. The Isolation Transformer completely isolates the boat from the shore ground. By connecting all metal parts to the neutral output on the secondary side of the transformer, a GFCI will trip or a fuse will blow in case of a short circuit.

    Reduce galvanic corrosion with an Isolation Transformer Victron Energy

     

    Isolation Transformers 2000 Watt (1) 3600 Watt (1) 3600 Watt Auto 115/230 V (1) 7000 Watt
    Input 115 or 230 V 115 or 230 V 115 / 230 V
    Automatic 115/230 V switching
    230 V
    Output 115 or 230 V 115 or 230 V 115 or 230 V 230 V
    Frequency 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz
    Rating 17 / 8,5 A 32 / 16 A 32 / 16 A 32 A
    Soft start Yes
    Transformer type Toroidal (low noise, low weight)
    Input circuit breaker yes
    ENCLOSURE
    Common Characteristics Material: aluminium (blue RAL 5012)Protection category: IP 21
    Weight 10 Kg 23 Kg 24 Kg 31 Kg
    Dimensions (h x w x d), mm 375x214x110 362 x 258 x 218
    STANDARDS
    Safety EN 60076
    1) Can be used as:
    115 V to 115 V isolation transformer
    115 V to 230 V isolation transformer
    230 V to 230 V isolation transformer
    230 V to 115 V isolation transformer
    SKU 3685
    Model # ITR050362041
    Barcode # 8719076022565
    Brand Victron Energy
    Shipping Weight 25.0000kg
    Shipping Width 0.295m
    Shipping Height 0.335m
    Shipping Length 0.435m
    Shipping Cubic 0.044880000m3