Shipping class: Free Shipping

Free Shipping
  • Victron Phoenix Inverter 48/3000 230V VE.Bus

    Victron Phoenix Inverter 48/3000 230V VE.Bus

    Technical details

    • Input voltage range 38 – 66VDC
    • Output 230VAC +/- 2% 50Hz +/- 0.1% (adjustable to 240V 60Hz)
    • Continuous output power @ 25degC 3000VA 2500W
    • Peak power 6000W
    • Efficiency 95%
    • Zero-load power 16W, in search mode 5W
    • Programmable relay which can be set for general alarm, DC undervoltage or genset start signal function
    • Enclosure made from aluminium, blue RAL5012, IP21 rating
    • Dimensions 362 x 258 x 218 (HxWxD) in mm
    • Weight 18kg

    Quick Install Guide

    Manual

    SKU 3186
    Model # PIN483020000
    Barcode # 8719076023852
    Brand Victron Energy
    Shipping Weight 19.6000kg
    Shipping Width 0.455m
    Shipping Height 0.315m
    Shipping Length 0.340m
    Shipping Cubic 0.050048000m3
  • Victron Phoenix Inverter 48/375 230V VE.Direct AU/NZ

    Victron Phoenix Inverter 48/375 230V VE.Direct AU/NZ

    SKU 3189
    Model # PIN483750300
    Barcode # 8719076034155
    Brand Victron Energy
    Shipping Weight 3.7500kg
    Shipping Width 0.300m
    Shipping Height 0.150m
    Shipping Length 0.210m
    Shipping Cubic 0.009450000m3
  • Victron Phoenix Inverter 48/5000 230V VE.Bus

    Victron Phoenix Inverter 48/5000 230V VE.Bus

    Technical details

    • Input voltage range 38 – 66VDC
    • Output 230VAC +/- 2% 50Hz +/- 0.1% (adjustable to 240V 60Hz)
    • Continuous output power @ 25degC 5000VA 4500W
    • Peak power 10kW
    • Efficiency 95%
    • Zero-load power 25W, in search mode 6W
    • Programmable relay which can be set for general alarm, DC undervoltage or genset start signal function
    • Enclosure made from aluminium, blue RAL5012, IP21 rating
    • Dimensions 444 x 328 x 240 (HxWxD) in mm
    • Weight 30kg

    Quick Install Guide

    Manual

    SKU 3187
    Model # PIN485020000
    Barcode # 8719076023883
    Brand Victron Energy
    Shipping Weight 31.0000kg
    Shipping Width 0.530m
    Shipping Height 0.340m
    Shipping Length 0.440m
    Shipping Cubic 0.079288000m3
  • Victron Quattro 48/10000/140-100/100 230V VE.Bus

    Victron Quattro 48/10000/140-100/100 230V VE.Bus

    The Quattro has two AC Inputs & two AC Outputs meaning two independent power sources can be connected, such as a generator or mains power. The Quattro automatically selects the input where voltage is present with the generator input taking priority.

    PowerControl is a valuable feature, especially when handling limited power such as generator supply. When the Quattro draws significant current from the generator or shore side supply, set the maximum current limit on each AC input. Considering other loads, the Quattro adapts so that only surplus power is used for charging, thus preventing the generator or mains supply from being overloaded.

    The PowerAssist feature will enable the device to supplement the incoming power with power from the battery. Any excess power is used for charging. It is therefore no longer necessary to size a generator on the maximum peak load. Use the most efficient size generator instead.

    The automatic and uninterruptible switching will ensure that if the power supply fails, the device will switch over to inverter operation so fast that loads will be unaffected, making this device an ideal choice for emergency power situations and telecommunications applications.

    For three-phase operation, three units can be configured, and additionally, potentially unlimited power supply can be achieved with the Multiple System Integration function, which allows for up to 6 Qattros [24/3000/70, for example], to operate in parallel providing 15kW / 18kVA output power and 420 Amps charging capacity.

    For split phase operation, two Quattros would be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30kW / 36kVA of split phase power.

    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.

    Configuring parallel and three-phase systems is made simple with the VEConfigure software tool – the Interface MK3-USB is required.

     

     

    Victron EasyPlus Basic Setup

     

    The basics of using VE Configure

     

    SKU 3253
    Model # QUA481030010
    Barcode # 8719076024200
    Brand Victron Energy
    Shipping Weight 57.0000kg
    Shipping Width 0.540m
    Shipping Height 0.380m
    Shipping Length 0.470m
    Shipping Cubic 0.096444000m3
  • Victron Quattro-II 48/5000/70-50/50

    Victron Quattro-II 48/5000/70-50/50

    A Quattro, plus ESS (Energy Storage System) functionality

    The Quattro-II can be connected to two independent AC sources, for example, the public grid and a generator, or two generators. The Quattro-II will automatically connect to the active source. Similar to the Victron Energy MultiPlus-II, the Quattro-II is also a combined inverter and charger. Additionally, it can accept two AC inputs and automatically connect to the active source. Its many features include a true sine wave inverter, adaptive charging, hybrid PowerAssist technology plus multiple system integration features such as three or split phase operation and parallel operation.

    Two AC Inputs & two AC Outputs

    The Quattro-II can be connected to two independent AC sources, for example, shore-side power and a generator, or two generators. The Quattro-II will automatically connect to the active source. The main output has no-break functionality. In the event of a grid failure, or shore or generator power being disconnected, the Quattro-II takes over the supply to the connected loads. This happens so fast (less than 20 milliseconds) that computers and other electronic equipment will continue to operate without disruption. The second output is live only when AC is available on one of the inputs of the Quattro-II. Loads that should not discharge the battery, such as air-conditioning or a water heater can be connected to this output.

    Unique PowerAssist and PowerControl feature

    The Quattro-II will prevent overload of a limited AC source, such as a generator or shore power connection. First, battery charging will automatically be reduced when otherwise an overload would occur. The second level will boost the output of a generator or shoreside supply with power taken from the battery. To implement PowerControl and
    PowerAssist and to optimise self-consumption with external current sensing, a Current Transformer Sensor 100A:50mA is required.

    A maximum grid or generator current can be set. The Quattro-II will then take account of other AC loads and use whatever is extra for battery charging, thus preventing the generator or grid from being overloaded (PowerControl function). PowerAssist takes the principle of PowerControl to a further dimension. Where peak power is so often required only for a limited period, the Quattro-II will compensate insufficient generator, shore or grid power with power from the battery. When the load reduces, the spare power is used to recharge the battery.

    Virtually unlimited power thanks to parallel operation

    Up to 6 Quattros-II can operate in parallel to achieve higher power output. Three phases or split phase operation is also possible.

    Parallel and 3 Phase operation

    Up to 6 Quatros can operate in parallel to achieve higher power output. Six 48/5000/70 units, for example, will provide 25 kW / 30 kVA output power with 420 Amps charging capacity. In addition to parallel connection, three units of the same model can be configured for three-phase output, and up to 6 sets of three units can be parallel connected per phase for a 75 kW / 90 kVA inverter and more than 1200 Amps charging capacity.

    Solar energy: AC power available even during a grid failure

    The Quattro-II can be used in off-grid as well as grid-connected PV and other alternative energy systems. It is compatible with both solar charger controllers and grid-tie inverters.

    On-site system configuring, monitoring and control

    Settings can be changed in a matter of minutes with VEConfigure software (computer or laptop and MK3-USB interface needed). Several monitoring and control options are available such as Victron Energys’ Cerbo GX, Bluetooth (with the optional VE.Bus Smart dongle), Battery Monitor, Digital Multi Control Panel.

    Remote configuring and monitoring

    Install a Cerbo GX or other GX product to connect to the internet. Operational data can be stored and displayed on Victron’s VRM (Victron Remote Management) website, free of charge. When connected to the internet, systems can be accessed remotely, and settings can be changed.

    Standard Marine, Mobile or Off-grid application

    Loads that should shut down when AC input power is not available can be connected to a second output. These loads will be taken into account by the PowerControl and  PowerAssist function in order to limit AC input current to a safe value when AC power is available.

     

    Application with MPPT Solar Charge Controller

     

    Quattro-II 48/5000/70-50
    PowerControl & PowerAssist Yes
    Transfer switch 50 A
    Maximum AC input current 50 A
    INVERTER
    DC Input voltage range 38-66 V
    Output Output voltage: 230 VAC ± 2% Frequency: 50 Hz ± 0,1% (1)
    Cont. output power at 25°C (3) 5000 VA
    Cont. output power at 25°C 4000 W
    Cont. output power at 40°C 3700 W
    Cont. output power at 65°C 3000 W
    Maximum apparent feed-in power 5000 VA
    Peak power 9000 W
    Maximum efficiency 96%
    Zero load power 18 W
    Zero load power in AES mode 12 W
    Zero load power in Search mode 2 W
    CHARGER
    AC Input Input voltage range: 187-265 VAC
    Input frequency: 45 – 65 Hz power factor: 1
    Charge voltage ‘absorption’ 57.6 V
    Charge voltage ‘float’ 55.2 V
    Storage mode 52.8 V
    Max. battery charge current (4) 70 A
    Battery temperature sensor Yes
    GENERAL
    Auxiliary output Yes (32A) Default setting: switches off when in inverter mode
    External AC current sensor
    (optional)
    100A
    Programmable relay (5) Yes
    Protection (2) a – g
    VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
    General purpose com. port Yes, 2x
    Remote on-off Yes
    Operating temperature range -40 to +65°C (fan assisted cooling)
    Humidity (non-condensing) max 95%
    ENCLOSURE
    Material & Colour Steel, blue RAL 5012
    Protection category IP22
    Battery-connection M8 bolts
    230 V AC-connection Screw terminals 13 mm² (6 AWG)
    Weight 30 kg
    Dimensions (hxwxd) 560 x 328 x 148 mm
    STANDARDS
    Safety EN-IEC 60335-1, EN-IEC 60335-2-29,
    EN-IEC 62109-1, EN-IEC 62109-2
    Emission, Immunity EN 55014-1, EN 55014-2
    EN-IEC 61000-3-2, EN-IEC 61000-3-3
    IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    Uninterruptible power supply Please consult the certificates on Victrons website.
    Anti-islanding Please consult the certificates on Victrons website.
    1) Can be adjusted to 60 Hz 3) Non-linear load, crest factor 3:1
    2) Protection key: 4) At 25°C ambient
    a) output short circuit 5) Programmable relay which can be set for general alarm, DC under voltage or
    b) overload genset start/stop function. AC rating: 230V / 4A, DC rating: 4A up to 35VDC and 1A
    c) battery voltage too high up to 60VDC
    d) battery voltage too low
    e) temperature too high
    f) 230 VAC on inverter output
    g) input voltage ripple too high
    SKU 3251
    Model # QUA482504010
    Barcode # 8719076054092
    Brand Victron Energy
    Shipping Weight 35.0000kg
    Shipping Width 0.340m
    Shipping Height 0.440m
    Shipping Length 0.530m
    Shipping Cubic 0.079288000m3
  • Victron Quattro 48/5000/70-100/100  230V VE.Bus

    Victron Quattro 48/5000/70-100/100 230V VE.Bus

    The Quattro has two AC Inputs & two AC Outputs meaning two independent power sources can be connected, such as a generator or mains power. The Quattro automatically selects the input where voltage is present with the generator input taking priority.

    PowerControl is a valuable feature, especially when handling limited power such as generator supply. When the Quattro draws significant current from the generator or shore side supply, set the maximum current limit on each AC input. Considering other loads, the Quattro adapts so that only surplus power is used for charging, thus preventing the generator or mains supply from being overloaded.

    The PowerAssist feature will enable the device to supplement the incoming power with power from the battery. Any excess power is used for charging. It is therefore no longer necessary to size a generator on the maximum peak load. Use the most efficient size generator instead.

    The automatic and uninterruptible switching will ensure that if the power supply fails, the device will switch over to inverter operation so fast that loads will be unaffected, making this device an ideal choice for emergency power situations and telecommunications applications.

    For three-phase operation, three units can be configured, and additionally, potentially unlimited power supply can be achieved with the Multiple System Integration function, which allows for up to 6 Qattros [24/3000/70, for example], to operate in parallel providing 15kW / 18kVA output power and 420 Amps charging capacity.

    For split phase operation, two Quattros would be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30kW / 36kVA of split phase power.

    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.

    Configuring parallel and three-phase systems is made simple with the VEConfigure software tool – the Interface MK3-USB is required.

     

     

    Victron EasyPlus Basic Setup

     

    The basics of using VE Configure

     

    SKU 3250
    Model # QUA485021010
    Barcode # 8719076024231
    Brand Victron Energy
    Shipping Weight 35.0000kg
    Shipping Width 0.530m
    Shipping Height 0.340m
    Shipping Length 0.440m
    Shipping Cubic 0.079288000m3
  • Victron Quattro 48/8000/110-100/100 230V VE.Bus

    Victron Quattro 48/8000/110-100/100 230V VE.Bus

    The Quattro has two AC Inputs & two AC Outputs meaning two independent power sources can be connected, such as a generator or mains power. The Quattro automatically selects the input where voltage is present with the generator input taking priority.

    PowerControl is a valuable feature, especially when handling limited power such as generator supply. When the Quattro draws significant current from the generator or shore side supply, set the maximum current limit on each AC input. Considering other loads, the Quattro adapts so that only surplus power is used for charging, thus preventing the generator or mains supply from being overloaded.

    The PowerAssist feature will enable the device to supplement the incoming power with power from the battery. Any excess power is used for charging. It is therefore no longer necessary to size a generator on the maximum peak load. Use the most efficient size generator instead.

    The automatic and uninterruptible switching will ensure that if the power supply fails, the device will switch over to inverter operation so fast that loads will be unaffected, making this device an ideal choice for emergency power situations and telecommunications applications.

    For three-phase operation, three units can be configured, and additionally, potentially unlimited power supply can be achieved with the Multiple System Integration function, which allows for up to 6 Qattros [24/3000/70, for example], to operate in parallel providing 15kW / 18kVA output power and 420 Amps charging capacity.

    For split phase operation, two Quattros would be stacked to provide 120-0-120V, and additional units can be paralleled up to a total of 6 units per phase, to supply up to 30kW / 36kVA of split phase power.

    The Quattro can be used in off grid as well as grid connected PV and other alternative energy systems. Loss of mains detection software is available.

    Configuring parallel and three-phase systems is made simple with the VEConfigure software tool – the Interface MK3-USB is required.

     

     

    Victron EasyPlus Basic Setup

     

    The basics of using VE Configure

     

    SKU 3252
    Model # QUA488024000
    Barcode # 8719076032953
    Brand Victron Energy
    Shipping Weight 44.0000kg
    Shipping Width 0.540m
    Shipping Height 0.380m
    Shipping Length 0.470m
    Shipping Cubic 0.096444000m3
  • Victron Inverter RS 48/6000 230V Smart Solar

    Victron Inverter RS 48/6000 230V Smart Solar

    The Inverter RS Smart Solar is a combination of a powerful 48VDC, 6kVA 230VAC inverter and a high voltage, 80-450VDC, 4kW MPPT solar charger. Thanks to its modern design and High Frequency (HF) technology the inverter only weighs 11kg and has an excellent efficiency, low standby power, and very quiet operation.

    The inverter is equipped with a display to read out battery, inverter, and solar charger details. These parameters can also be read out via Bluetooth by the VictronConnect App. In addition to this, the inverter has a VE.Direct and a VE.Can Port, for connection to a GX device for system monitoring.

    Off-Grid solar inverter

    The Inverter RS Smart Solar 48/6000 is a 48V 6kVA Inverter with 450VDC 4kWp PV input. It is used in off-grid solar applications where AC power is required.

    Combination of an inverter, bi-directional DC-DC converter and MPPT

    The inverter produces a perfect sine wave, able to supply high powered appliances. It is supplied by a bi-directional DC-DC converter, that can either charge the battery when excess solar power is available or convert from the battery when it is needed.

    Wide MPPT voltage range

    80 – 450VDC, with a 120VDC PV startup voltage.

    Light weight, efficient and quiet

    Thanks to high frequency technology and a new design this powerful inverter weighs only 11kg. In addition to this it has an excellent efficiency, low standby power, and a very quiet operation.

    Display and Bluetooth

    The display reads battery, inverter and solar charge controller parameters. The same parameters can be accessed with a smartphone or other Bluetooth enabled device. In addition, Bluetooth can be used to set up the system and to change settings with VictronConnect.

    Support for AC and DC coupled PV battery charging

    The Inverter RS supports the connection of AC coupled PV inverters on the AC output up to 6kVA, and a total battery charging capacity of up to 100A. Frequency Shift Power Control is enabled out of the box, without the need for configuration, reducing installation time.

    VE.Can and VE.Direct port

    For connection to a GX device for system monitoring, data logging, and remote firmware updates.

    Built in PV isolator

    Both parallel PV strings connected to the MC4 plugs can be safely isolated with the large built-in switch on the bottom of the unit.

    I/O Connections

    I/O Connections Programmable Relay, temperature sensor and voltage sensor connections. The remote input can also be configured to accept the Victron miniBMS.

    Inverter RS Smart Solar

    48/6000 SPECIFICATIONS

    INVERTER
    DC Input voltage range Output
    Continuous output power at 25°C
    38 – 64 V (6)
    Output voltage: 230 VAC ± 2%
    Frequency: 50 Hz ± 0.1% (1)
    Increases linearly from 4800 W at 46 VDC to 5300 W at 52 VDC
    Continuous output power at 40°C 4500W
    Continuous output power at 65°C 3000W
    Peak power 9 kW for 3 seconds
    Short-circuit output current 50A
    Maximum efficiency 96.5% at 1 kW load
    94% at 5 kW load
    Zero load power 20W
    SOLAR
    Maximum DC voltage 450V
    Nominal DC voltage 300V
    Start-up voltage 120V
    MPPT operating voltage range 80 – 450V (5)
    DC input current limit Maximum DC input current 18A (4)
    20A
    Maximum PV input power 4000W
    Maximum DC charging power 4000W
    Earth leakage trip level 30 mA
    CHARGER
    Charge voltage ‘absorption’ (V DC) 57.6V
    Charge voltage ‘float’ (V DC) 55.2V
    Maximum charge current 100A
    Battery temperature sensor Yes
    GENERAL
    Parallel and 3-phase operation No
    Programmable relay (3) Yes
    Protection (2) a – f
    Data Communications Ports VE.Direct port and VE.Can port
    General purpose analogue/digital
    in port
    Yes, 2x
    Remote on-off Yes
    Operating temperature range -40 to +65°C (fan assisted cooling)
    Humidity (non-condensing) max 95%
    ENCLOSURE
    Material & Colour steel, blue RAL 5012
    Protection category IP22
    Battery-connection M8 bolts
    230 V AC-connection Screw terminals 13 mm² (6 AWG)
    Weight 11 kg
    Dimensions (hxwxd) 425 x 440 x 125 mm
    STANDARDS
    Safety EN-IEC 60335-1, EN-IEC 60335-2-29,
    EN-IEC 62109-1, EN-IEC 62109-2
    Emission, Immunity EN 55014-1, EN 55014-2
    EN-IEC 61000-3-2, EN-IEC 61000-3-3
    IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
    1) Can be adjusted to 60 Hz
    2) Protection key:
    a) output short circuit
    b) overload
    c) battery voltage too high
    d) battery voltage too low
    e) temperature too high
    f) 230 VAC on inverter output
    3) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4A up to 35VDC and 1A up to 70VDC
    4) Normal operation is regulated to 18A, with maximum reverse polarity protection 20A.
    5) MPPT operating range is also constrained by battery voltage – PV VOC should not exceed 8x battery float voltage, e.g. a 50V battery voltage maximum should have 400V maximum PV array. – see product manual for further information.
    6) Minimum start-up voltage is 41V. Inverter shutdown can be set as low as 32V DC, but may shut down on low AC output voltage (due to load). Over-voltage disconnect is 65.5V. Charger set- point can be set to max 62V. The charge current derates above 57V.
    SKU 3167
    Model # PIN482601000
    Barcode # 8719076048176
    Brand Victron Energy
    Shipping Weight 14.0000kg
    Shipping Width 0.535m
    Shipping Height 0.230m
    Shipping Length 0.485m
    Shipping Cubic 0.060858000m3
    Unit Of Measure ea
  • Victron Battery Monitor BMV-700H

    Victron Battery Monitor BMV-700H

    SKU 3494
    Model # BAM010700100
    Barcode # 8719076020080
    Brand Victron Energy
    Shipping Weight 1.0670kg
    Shipping Width 0.210m
    Shipping Height 0.065m
    Shipping Length 0.210m
    Shipping Cubic 0.028665000m3
  • Victron Battery Monitor BMV-702

    Victron Battery Monitor BMV-702

    The BMV monitors the voltage and current of a single battery bank and calculates power, state-of-charge, and time-to-go. The BMV-702 features an additional voltage input that can be used to measure an auxiliary or starter battery voltage, midpoint voltage or temperature with the optional temperature sensor. Data can be transferred to smartphones or computers with the optional Bluetooth dongle and external alarms can be triggered with the relay contact.

    Installation is simply a case of connecting the supplied shunt in the negative battery cable, mounting the monitor in a 52mm diameter hole and connecting the wires. An optional wall enclosure is available if surface mounting is preferred. 

     

    How to set up a Victron BMV Battery Monitor for lead and lithium batteries

     

    SKU 3490R
    Model # BAM010702000R
    Barcode # 8719076020103
    Brand Victron Energy
    Shipping Weight 1.0500kg
    Shipping Width 0.230m
    Shipping Height 0.280m
    Shipping Length 0.070m
    Shipping Cubic 0.045080000m3
  • Victron Battery Monitor BMV-702 Retail

    Victron Battery Monitor BMV-702 Retail

    The BMV monitors the voltage and current of a single battery bank and calculates power, state-of-charge, and time-to-go. The BMV-702 features an additional voltage input that can be used to measure an auxiliary or starter battery voltage, midpoint voltage or temperature with the optional temperature sensor. Data can be transferred to smartphones or computers with the optional Bluetooth dongle and external alarms can be triggered with the relay contact.

    Installation is simply a case of connecting the supplied shunt in the negative battery cable, mounting the monitor in a 52mm diameter hole and connecting the wires. An optional wall enclosure is available if surface mounting is preferred. 

     

    How to set up a Victron BMV Battery Monitor for lead and lithium batteries

     

    SKU 3491
    Model # BAM010702000R
    Barcode # 8719076020103
    Brand Victron Energy
    Shipping Weight 1.0500kg
    Shipping Width 0.230m
    Shipping Height 0.280m
    Shipping Length 0.070m
    Shipping Cubic 0.045080000m3