Your cart is currently empty!
Shipping class: Free Shipping
Victron BlueSolar MPPT 100/50
This Model does NOT have bluetooth capabilities.
For bluetooth features, Victron BlueSolar Controllers require the V.E.Direct Bluetooth Smart dongle.
For in-built Bluetooth please view the SmartSolar range.
The smartsolar version for this model can be viewed here: Victron SmartSolar MPPT 100/50MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The Victron MPPT BlueSolar senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The BlueSolar supports Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximum energy by locking to the optimum MPP. In addition the unit is configured for optimal Three step charging.
With the V.E.Direct Bluetooth Smart dongle , programming, real-time data and history display is available on your smart device.
Inbuilt additional electronic protection provides
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
- Internal temperature sensor compensates absorption and float charge voltage for temperature.
Other features:
- With no cooling fan the maximum efficiency exceeds 98%.
- Flexible charge algorithm provides functionality for fully programmable charge algorithm, and eight pre-programmed algorithms, selectable with a rotary switch
Three Stage Charging
- Stage One – Bulk or Boost – As much current as possible is delivered in order to rapidly recharge the batteries to about 80%.
- Stage Two – Absorption – When the battery reaches its final charging voltage, known as its absorption voltage the charge allows the current to taper off as the battery nears a full charge.
- Stage Three – Float – At this stage float voltage is applied which is enough to retain a full charge but controlled to prevent overcharging.
MPPT 100/30 & 100/50 Specifications
SKU 3721 Model # SCC020050200 Barcode # 8719076025566 Brand Victron Energy Shipping Weight 1.5300kg Shipping Width 0.205m Shipping Height 0.090m Shipping Length 0.130m Shipping Cubic 0.024570000m3 Victron SmartSolar MPPT 75/10 Retail
MPPT 75/10, 75/15, 100/15, 100/20, 100/20-48V
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
Load output will prevent the battery from becoming totally flat [which can cause damage]. A preset discharge level can be configured at which point the SmartSolar will disconnect the load preventing the battery draining further.
Alternatively, the inbuilt intelligent battery management feature in the SmartSolar can be set. Known as Battery Life the feature is designed to protect and better maintain your battery by ensuring 100% recharge is regularly reached. SmartSolar attempts a daily 100% recharge. During periods of poor weather or low light conditions, it raises the disconnect voltage until successful.
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- Load Output [100/20 and smaller]
- Load current – shows the current being drawn by appliances
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 75/50, the first number is the maximum PV open circuit voltage. The second number, 50, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 75/10, 75/15, 100/15, 100/20, 100/20-48V Specifications
SKU 3730 Model # SCC075010060R Barcode # 8719076040798 Brand Victron Energy Shipping Weight 0.4700kg Shipping Width 0.210m Shipping Height 0.050m Shipping Length 0.150m Shipping Cubic 0.015750000m3 Victron SmartSolar MPPT 75/15 Retail
MPPT 75/10, 75/15, 100/15, 100/20, 100/20-48V
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
Load output will prevent the battery from becoming totally flat [which can cause damage]. A preset discharge level can be configured at which point the SmartSolar will disconnect the load preventing the battery draining further.
Alternatively, the inbuilt intelligent battery management feature in the SmartSolar can be set. Known as Battery Life the feature is designed to protect and better maintain your battery by ensuring 100% recharge is regularly reached. SmartSolar attempts a daily 100% recharge. During periods of poor weather or low light conditions, it raises the disconnect voltage until successful.
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- Load Output [100/20 and smaller]
- Load current – shows the current being drawn by appliances
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 75/50, the first number is the maximum PV open circuit voltage. The second number, 50, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 75/10, 75/15, 100/15, 100/20, 100/20-48V Specifications
SKU 3731 Model # SCC075015060R Barcode # 8719076040804 Brand Victron Energy Shipping Weight 0.6840kg Shipping Width 0.210m Shipping Height 0.050m Shipping Length 0.150m Shipping Cubic 0.015750000m3 Victron SmartSolar MPPT 100/15 Retail
MPPT 75/10, 75/15, 100/15, 100/20, 100/20-48V
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
Load output will prevent the battery from becoming totally flat [which can cause damage]. A preset discharge level can be configured at which point the SmartSolar will disconnect the load preventing the battery draining further.
Alternatively, the inbuilt intelligent battery management feature in the SmartSolar can be set. Known as Battery Life the feature is designed to protect and better maintain your battery by ensuring 100% recharge is regularly reached. SmartSolar attempts a daily 100% recharge. During periods of poor weather or low light conditions, it raises the disconnect voltage until successful.
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- Load Output [100/20 and smaller]
- Load current – shows the current being drawn by appliances
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 75/50, the first number is the maximum PV open circuit voltage. The second number, 50, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 75/10, 75/15, 100/15, 100/20, 100/20-48V Specifications
SKU 3732 Model # SCC110015060R Barcode # 8719076040811 Brand Victron Energy Shipping Weight 0.7700kg Shipping Width 0.210m Shipping Height 0.050m Shipping Length 0.150m Shipping Cubic 0.015750000m3 Victron SmartSolar MPPT 100/20_( Up to 48v )
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
Load output will prevent the battery from becoming totally flat [which can cause damage]. A preset discharge level can be configured at which point the SmartSolar will disconnect the load preventing the battery draining further.
Alternatively, the inbuilt intelligent battery management feature in the SmartSolar can be set. Known as Battery Life the feature is designed to protect and better maintain your battery by ensuring 100% recharge is regularly reached. SmartSolar attempts a daily 100% recharge. During periods of poor weather or low light conditions, it raises the disconnect voltage until successful.
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- Load Output [100/20 and smaller]
- Load current – shows the current being drawn by appliances
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 75/50, the first number is the maximum PV open circuit voltage. The second number, 50, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
SKU 3733 Model # SCC110020160R Barcode # 8719076043027 Brand Victron Energy Shipping Weight 0.8600kg Shipping Width 0.210m Shipping Height 0.050m Shipping Length 0.150m Shipping Cubic 0.015750000m3 Victron BlueSolar MPPT 100/20_( Up to 48V )
This Model does NOT have bluetooth capabilities.
For bluetooth features, Victron BlueSolar Controllers require the V.E.Direct Bluetooth Smart dongle.
For in-built Bluetooth please view the SmartSolar range.
The smartsolar version for this model can be viewed here: Victron SmartSolar MPPT 100/20_( Up to 48v )MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The Victron MPPT BlueSolar senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The BlueSolar supports Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximum energy by locking to the optimum MPP. In addition the unit is configured for optimal Three Step Charging.
With the V.E.Direct Bluetooth Smart dongle, programming, real-time data and history display is available on your smart device.
Inbuilt additional electronic protection provides
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Three Stage Charging
- Stage One – Bulk or Boost – As much current as possible is delivered in order to rapidly recharge the batteries to about 80%.
- Stage Two – Absorption – When the battery reaches its final charging voltage, known as its absorption voltage the charge allows the current to taper off as the battery nears a full charge.
- Stage Three – Float – At this stage float voltage is applied which is enough to retain a full charge but controlled to prevent overcharging.
MPPT 75/10, 75/15 & MPPT 100/15 Specifications
SKU 3718 Model # SCC110020170R Barcode # 8719076049845 Brand Victron Energy Shipping Weight 0.6000kg Shipping Width 0.210m Shipping Height 0.050m Shipping Length 0.150m Shipping Cubic 0.015750000m3 Victron SmartSolar MPPT 100/30
MPPT 100/30 & 100/50
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The Victron MPPT SmartSolar support Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximin energy by locking to the optimum MPP.
Internal temperature sensor provides additional electronic protection
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Other features:
- With no cooling fan the maximum efficiency exceeds 98%.
- Flexible charge algorithm provides functionality for fully programmable charge algorithm, and eight preprogrammed algorithms, selectable with a rotary switch
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 100/30, the first number is the maximum PV open circuit voltage. The second number, 30, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 100/30 & 100/50 Specifications
SKU 3734 Model # SCC110030210 Barcode # 8719076040170 Brand Victron Energy Shipping Weight 1.5200kg Shipping Width 0.205m Shipping Height 0.090m Shipping Length 0.130m Shipping Cubic 0.024570000m3 Victron SmartSolar MPPT 100/50
MPPT 100/30 & 100/50
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The Victron MPPT SmartSolar support Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximin energy by locking to the optimum MPP.
Internal temperature sensor provides additional electronic protection
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Other features:
- With no cooling fan the maximum efficiency exceeds 98%.
- Flexible charge algorithm provides functionality for fully programmable charge algorithm, and eight preprogrammed algorithms, selectable with a rotary switch
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 100/30, the first number is the maximum PV open circuit voltage. The second number, 30, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 100/30 & 100/50 Specifications
SKU 3735 Model # SCC110050210 Barcode # 8719076040194 Brand Victron Energy Shipping Weight 1.5300kg Shipping Width 0.205m Shipping Height 0.090m Shipping Length 0.130m Shipping Cubic 0.024570000m3 Victron SmartSolar MPPT 150/35
MPPT 150/35
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The Victron MPPT SmartSolar support Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximin energy by locking to the optimum MPP.
Internal temperature sensor provides additional electronic protection
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Other features:
- With no cooling fan the maximum efficiency exceeds 98%.
- Flexible charge algorithm provides functionality for fully programmable charge algorithm, and eight preprogrammed algorithms, selectable with a rotary switch
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 100/30, the first number is the maximum PV open circuit voltage. The second number, 30, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 150/35 Specifications
SKU 3736 Model # SCC115035210 Barcode # 8719076040187 Brand Victron Energy Shipping Weight 1.5300kg Shipping Width 0.240m Shipping Height 0.090m Shipping Length 0.130m Shipping Cubic 0.002808000m3 Victron SmartSolar MPPT 150/45
A solar charger gathers energy from your solar panels, and stores it in your batteries. Using the latest, fastest technology, SmartSolar maximises this energy-harvest, driving it intelligently to achieve full charge in the shortest possible time. SmartSolar maintains battery health, extending its life.
The SmartSolar charge controller will even recharge a severely depleted battery. It can operate with a battery voltage as low as 0 Volts, provided the cells are not permanently sulphated or otherwise damaged.
SmartSolar Charge Controller MPPT 150/45
MPPT: Ultra Fast Maximum Power Point Tracking
By constantly monitoring the voltage and current output of your solar (PV) panels, MPPT technology ensures that every drop of available power is rinsed out of your panels, and harvested for storage. The advantage of this is most noticeable when the sky is partially clouded, and light intensity is constantly changing.
Advanced Maximum Power Point Detection in case of partial shading conditions
If partial shading occurs, two or more maximum power points may be present on the power-voltage curve. Conventional MPPTs tend to lock to a local MPP, which may not be the optimum MPP. The innovative BlueSolar algorithm will always maximize energy harvest by locking to the optimum MPP.
Remote Monitoring and Control
Remotely control and monitor the extensive features of your SmartSolar MPPT charger with built-in Bluetooth by pairing it with your smartphone or another device via VictronConnect. If your installation is connected to the internet with a GX device, the Victron Remote Management Portal (VRM) provides access to the full power of your MPPT, anytime, anywhere; both VictronConnect and VRM are free to use. For remote installations – even when there is no internet connection nearby – you may be able to monitor your MPPT by connecting the GlobalLink 520.
Bluetooth Smart built-in
The wireless solution to set up, monitor, update and synchronise SmartSolar Charge Controllers.
Fully discharged battery recovery function
Will initiate charging even if the battery has been discharged to zero volts. Will reconnect to a fully discharged Li-ion battery with an integrated disconnect function.
Flexible charge algorithm
Fully programmable charge algorithm, and eight preprogrammed algorithms, selectable with a rotary switch.
Extensive electronic protection
– Over-temperature protection and power derating when the temperature is high.
– PV short circuit and PV reverse polarity protection.
– PV reverse current protection.SmartSolar Charge Controller MPPT 150/35 MPPT 150/45 Battery voltage 12 / 24 / 48V Auto Select
(software tool needed to select 36V)Rated charge current 35A 45A Nominal PV power 1a, b) 35A 12V: 500W / 24V: 1000W / 36V: 1500W / 48V: 2000W
45A 12V: 650W / 24V: 1300W / 36V: 1950W / 48V: 2600WMax. PV short circuit current 2) 40A 50A Maximum PV open circuit voltage 150V absolute maximum coldest conditions
145V start-up and operating maximumMaximum efficiency 98% Self-consumption 12V: 20mA 24V: 15mA 48V: 10mA Charge voltage ‘absorption’ Default setting: 14,4 / 28,8 / 43,2 / 57,6V (adjustable) Charge voltage ‘float’ Default setting: 13,8 / 27,6 / 41,4 / 55,2V (adjustable) Charge algorithm multi-stage adaptive (eight pre-programmed algorithms) Temperature compensation -16 mV / -32 mV / -64 mV / °C Protection PV reverse polarity / output short circuit / over-temperature Operating temperature -30 to +60°C (full rated output up to 40°C) Humidity 95%, non-condensing Data communication port VE.Direct
See the data communication white paper on our websiteENCLOSURE Colour Blue (RAL 5012) Power terminals 16 mm² / AWG6 Protection category IP43 (electronic components), IP22 (connection area) Weight 1,25 kg Dimensions (h x w x d) 130 x 186 x 70 mm STANDARDS Safety EN/IEC 62109-1, UL 1741, CSA C22.2 SKU 3737 Model # SCC115045212 Barcode # 8719076053026 Brand Victron Energy Shipping Weight 1.5300kg Shipping Width 0.300m Shipping Height 0.090m Shipping Length 0.130m Shipping Cubic 0.003510000m3 Unit Of Measure ea Victron SmartSolar MPPT 150/60-Tr
MPPT 150/45 up to 150/100
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The Victron MPPT SmartSolar support Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximin energy by locking to the optimum MPP.
Internal temperature sensor provides additional electronic protection
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Other features:
- With no cooling fan the maximum efficiency exceeds 98%.
- Flexible charge algorithm provides functionality for fully programmable charge algorithm, and eight pre-programmed algorithms, selectable with a rotary switch
- Remote on-off [To connect for example to a BMS]
- Programmable relay to set the device to trip on alarm or other events
- Optional SmartSolar pluggable LCD display
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 150/45, the first number is the maximum PV open circuit voltage. The second number, 45, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 150/45 up to 150/100 Specifications
SKU 3738 Model # SCC115060211 Barcode # 8719076051381 Brand Victron Energy Shipping Weight 4.0500kg Shipping Width 0.270m Shipping Height 0.150m Shipping Length 0.250m Shipping Cubic 0.010125000m3 Victron SmartSolar MPPT 150/70-Tr
MPPT 150/45 up to 150/100
MPPT controllers operate solar panels at their Maximum Power Point improving efficiency up to 30% by adjusting input voltage to harvest the maximum power from the solar panels. It then manages this power to supply the varying voltage requirement of the battery plus load.
The MPPT senses when to adjust the output that it is being sent to the battery and will shut down for a few microseconds, calculate and make relevant adjustments. The principle of MPPT is to extract the maximum possible power from a solar panel by setting the most efficient combination of voltage and current – maximum power point.
The Victron MPPT SmartSolar support Advanced Maximum Power Point Detection. Unlike the conventional MPPTs which tend to lock to a local MPP when shady conditions occur, [which may not be the optimum MPP], Advance Maximum Power Point Detection will harvest maximin energy by locking to the optimum MPP.
Internal temperature sensor provides additional electronic protection
- Over-temperature protection and power derating when temperature is high.
- PV short circuit and PV reverse polarity protection.
- PV reverse current protection.
Other features:
- With no cooling fan the maximum efficiency exceeds 98%.
- Flexible charge algorithm provides functionality for fully programmable charge algorithm, and eight pre-programmed algorithms, selectable with a rotary switch
- Remote on-off [To connect for example to a BMS]
- Programmable relay to set the device to trip on alarm or other events
- Optional SmartSolar pluggable LCD display
Built-in Bluetooth along with the VictronConnect App provides easy access to the extensive range of functions available on your solar charge controller such as:
- Solar Gauge – Realtime power output
- Battery Voltage
- Battery Current
- Battery State
- History Analysis
- Various Settings
Victron MPPT model names explained
MPPT 150/45, the first number is the maximum PV open circuit voltage. The second number, 45, is the maximum charge current. Use the Victron MPPT Excel sheet or Online MPPT Calculator for PV sizing calculations.
For more information about PWM or MPPT charge controllers, read the Victron whitepaper: which solar charge controller: PWM or MPPT?
MPPT 150/45 up to 150/100 Specifications
SKU 3740 Model # SCC115070211 Barcode # 8719076051404 Brand Victron Energy Shipping Weight 4.0500kg Shipping Width 0.270m Shipping Height 0.150m Shipping Length 0.250m Shipping Cubic 0.010125000m3